μPADs for Chemistry Education and Acetic Acid Analysis: A Literature Review

Authors

  • Medardus Josua Petrus Tosang Study Program of Chemistry Education, Faculty of Teacher Training and Education, Tanjungura University, Jl. Prof. Dr. H. Hadari Nawawi, Pontianak, Indonesia
  • Masriani Study Program of Chemistry Education, Faculty of Teacher Training and Education, Tanjungura University, Jl. Prof. Dr. H. Hadari Nawawi, Pontianak, Indonesia
  • Firman Shantya Budi Study Program of Chemistry, Faculty of Mathematics and Natural Sciences, Tanjungura University, Jl. Prof. Dr. H. Hadari Nawawi, Pontianak, Indonesia

DOI:

https://doi.org/10.33394/hjkk.v14i3.20631

Keywords:

μPAD, Chemistry Education, Acetic Acid Analysis, Acid Base Titration, Green Chemistry

Abstract

Microfluidic paper-based analytical devices (μPADs) have emerged as promising analytical platforms due to their low cost, portability, simplicity, and minimal reagent requirements. These characteristics make μPADs attractive for both chemical analysis and chemistry education, particularly in laboratory activities that emphasize sustainable and environmentally friendly practices. This literature review aims to examine the development and application of μPADs in chemistry learning and acetic acid determination through acid–base titration experiments. A descriptive literature review with a qualitative approach was conducted using articles published between 2016 and 2025. Relevant literature was identified through Google Scholar, ScienceDirect, PubMed, and ACS Publications using keywords related to μPADs, chemistry education, acid–base titration, and acetic acid analysis. Following a screening and eligibility assessment process, 21 peer-reviewed articles were selected and analyzed using qualitative content analysis. The findings indicate that μPADs serve not only as analytical tools but also as instructional media that support the understanding of acid–base reactions, stoichiometry, limiting reagents, and titration concepts through microscale experimentation. In acetic acid analysis, distance-based and colorimetric μPADs integrated with smartphone-assisted image processing provide results comparable to conventional titration methods while reducing reagent consumption, analysis time, and chemical waste generation. The integration of digital image analysis also introduces students to modern analytical techniques and enhances digital literacy skills. Despite challenges related to fabrication standardization and analytical reproducibility, μPADs demonstrate considerable potential for implementation in higher education laboratories as cost-effective and sustainable tools that support green analytical chemistry practices.

References

Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018). Review on microfluidic paper-based analytical devices towards commercialisation. Analytica chimica acta, 1001, 1-17

Alahmad, W., Tungkijanansin, N., Kaneta, T., & Varanusupakul, P. (2018). A colorimetric paper-based analytical device coupled with hollow fiber membrane liquid phase microextraction (HF-LPME) for highly sensitive detection of hexavalent chromium in water samples. Talanta, 190, 78-84.

Almeida, M. I. G., Jayawardane, B. M., Kolev, S. D., & McKelvie, I. D. (2018). Developments of microfluidic paper-based analytical devices (μPADs) for water analysis: A review. Talanta, 177, 176-190.

Anggraini, D. P. (2016). Analisis kesulitan mahasiswa dalam perkuliahan dan praktikum kimia dasar di jurusan pendidikan biologi FKIP UNISBA. Konstruktivisme: Jurnal Pendidikan Dan Pembelajaran, 8(1), 61-71.

Boobphahom, S., Nguyet Ly, M., Soum, V., Pyun, N., Kwon, O. S., Rodthongkum, N., & Shin, K. (2020). Recent advances in microfluidic paper-based analytical devices toward high-throughput screening. Molecules, 25(13), 2970.

Chen, J. L., Njoku, D. I., Tang, C., Gao, Y., Chen, J., Peng, Y. K., Sun, H., Mao, G., Pan, M.,& Tam, N. F. Y. (2024). Advances in Microfluidic Paper‐Based Analytical Devices (µPADs): Design, Fabrication, and Applications. Small Methods, 8(11), 2400155.

Damayanti, N. K. A., Maryam, S., & Subagia, I. W. (2019). Analisis pelaksanaan praktikum kimia. Jurnal Pendidikan Kimia Undiksha, 3(2), 52-60.

Dias, L. G., Duarte, L. C., Pinheiro, K. M., Moreira, N. S., & Coltro, W. K. (2023). Distance-based paper microfluidics as environmentally friendly platforms for monitoring acid-base titrations. Talanta Open, 7, 100216.

Dona, R., Ningrum, T. E. W., Hamzah, F., & Wahyuni, D. T. (2024). Penentuan Penentuan Kadar Asam Asetat Dalam Larutan Cuka Makan Yang Beredar Di Pekanbaru Dengan Metode Alkalimetri. Jurnal Penelitian Farmasi Indonesia, 13(1), 18-22.

Erkocyigit, B. A., Ozufuklar, O., Yardim, A., Celik, E. G., & Timur, S. (2023). Biomarker Detection in Early Diagnosis of Cancer: Recent Achievements in Point-of-Care Devices Based on Paper Microfluidics. Biosensors, 13(3), 387.

Gonzalez, G. G., Zonetti, P. C., Silveira, E. B., Mendes, F. M., de Avillez, R. R., Rabello, C. R., Zotin, F. M. Z., & Appel, L. G. (2019). Two mechanisms for acetic acid synthesis from ethanol and water. Journal of Catalysis, 380, 343-351.

Huang, J., & Cai, L. (2022). A comprehensive experiment for training undergraduates majoring in nutrition education using a paper-based micro acid–base titration. Journal of Chemical Education, 99(10), 3607-3612.

Jarujamrus, P., Prakobkij, A., Puchum, S., Chaisamdaeng, S., Meelapsom, R., Anutrasakda, W., Amatatongchai, M., Chairam, S., & Citterio, D. (2020). Acid–base titration using a microfluidic thread-based analytical device (μTAD). Analyst, 145(13), 4457-4466.

Komatsu, T., Mohammadi, S., Busa, L. S. A., Maeki, M., Ishida, A., Tani, H., & Tokeshi, M. (2016). Image analysis for a microfluidic paper-based analytical device using the CIE L* a* b* color system. Analyst, 141(24), 6507-6509.

Kuna, M. R. (2023). Penetapan Kadar Produk Makanan Asam Cuka (Ch3Cooh) Yang Beredar Dipasaran. Dalton: Jurnal Pendidikan Kimia dan Ilmu Kimia, 6(2), 111-115.

Lawrence, K. Y., Tam, S. K., Ng, T. N., & Ng, K. M. (2025). Product design: Microfluidic paper-based analytical device. Chemical Engineering Research and Design.

Le, P. G., & Cho, S. (2025). Microfluidic Paper-Based Sensors and Their Applications for Glucose Sensing. Chemosensors, 13(8), 293.

Lim, H., Jafry, A. T., & Lee, J. (2019). Fabrication, flow control, and applications of microfluidic paper-based analytical devices. Molecules, 24(16), 2869.

Mazwan, M., Mauliza, E., Sakdiah, H., Minarni, M., Amaluddin, A., & Wahidi, J. (2024). Peranan Kimia Lingkungan dalam Pengembangan Kebijakan Geografi Berkelanjutan. Jurnal Agroristek, 7(2), 71–79

Meredith, N. A., Quinn, C., Reilly, T. H., Volckens, J., & Henry, C. (2016). Paper-Based Analytical Devices For Environmental Analysis. Analyst, 141(6), 1874–1887.

Mulu, T., Tibebe, D., Kassa, Y., Amare, A., Mulugeta, M., Moges, Z., Zewdu, Z., & Mustofa, S. (2024). Recent Advances in the Application of Microfluidic Paper Based Devices for Environment Sample Analysis. Biomed. J. Sci. Tech. Res., 59, 51491-51506.

Musile, G., Grazioli, C., Fornasaro, S., Dossi, N., De Palo, E. F., Tagliaro, F., & Bortolotti, F. (2023). Application of paper-based microfluidic analytical devices (µPAD) in forensic and clinical toxicology: A review. Biosensors, 13(7), 743.

Namwong, P., Jarujamrus, P., Amatatongchai, M., & Chairam, S. (2018). Fabricating simple wax screen-printing paper-based analytical devices to demonstrate the concept of limiting reagent in acid–base reactions. Journal of Chemical Education, 95(2), 305-309.

Nogueira, S. A., Sousa, L. R., Silva, N. K., Rodrigues, P. H., & Coltro, W. K. (2017). Monitoring acid–base titrations on wax printed paper microzones using a smartphone. Micromachines, 8(5), 139.

Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021). Microfluidic paper-based analytical devices: from design to applications. Chemical reviews, 121(19), 11835-11885.

Sokpheak, T., Chong, A., Un, S., & Soum, V. (2024). Fabrication of a Paper-Based Microfluidic Device Using a Simple Method for Chemical Analysis,” Cambodia Journal of Education and STEM. 2(2), 114–129. https://doi.org/10.62219/cjes.2024228

Souza, D. S., Fernandes, G. M., Dias, B. C., Stefanelli Junior, J. R., Sequinel, R., & Petruci, J. F. S. (2022). A Green Analytical Methodology for Detecting Adulteration in Automotive Urea-SCR Products Using Microfluidic-Paper Analytical Devices. Sustainability, 14(6), 3363.

Sulistyarti, H., Puspitaloka, P. A., Putra, B. I., Retnowati, R., & Tolle, H. (2021). Microfluidic paper-based analytical device (μpad) for determining hydroquinone in facial whitening cream using phloroglucinol reagent. Makara Journal of Science, 25(2), 7.

Wisang, Y. F., Sulistyarti, H., Andayani, U., & Sabarudin, A. (2019, June). Microfluidic Paper-based Analytical Devices (µPADs) For Analysis Lead Using Naked Eye and Colorimetric Detections. In IOP Conference Series: Materials Science and Engineering, 546(3), 032033. IOP Publishing.

Xu, C., Cai, L., & Huang, Z. (2024). Ultra-microscale chemistry experiment on microfluidic devices: a new trend in chemical education. Journal of Chemical Education, 101(4), 1564-1573.

Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015). Paper‐based inkjet‐printed microfluidic analytical devices. Angewandte Chemie International Edition, 54(18), 5294-5310.

Published

2026-06-30

How to Cite

Tosang, M. J. P., Masriani, & Budi, F. S. (2026). μPADs for Chemistry Education and Acetic Acid Analysis: A Literature Review. Hydrogen: Jurnal Kependidikan Kimia, 14(3). https://doi.org/10.33394/hjkk.v14i3.20631

Issue

Section

Articles